Skip to content

HOWTO: Configure VLAN-Aware Bridge and VLAN Subinterfaces on Proxmox

Purpose: Configure a VLAN-aware bridge (vmbr0) and per-VLAN gateway interfaces on a Proxmox host, aligned with the HybridOps Studio VLAN plan (management, observability, dev, staging, prod, lab).
Difficulty: Intermediate
Target host: Proxmox VE hypervisor (single-node homelab)


Demo / Walk-through

▶ Watch the demo

If the embed does not load, use the direct link:
Open on YouTube

1. Prerequisites

  • Proxmox VE installed and reachable on the management LAN.
  • SSH or console access with root privileges.
  • Host has at least one physical NIC connected to the upstream router/switch (e.g. enp87s0).
  • No NetworkManager managing interfaces (standard Proxmox /etc/network/interfaces model).
  • Backup of current network configuration.

Backup current config:

cp /etc/network/interfaces /etc/network/interfaces.backup-$(date +%Y%m%d-%H%M%S)

2. Define VLAN Plan

HybridOps Studio uses the following VLAN and subnet layout (see ADR-0101):

VLAN Subnet Purpose
10 10.10.0.0/24 Management
11 10.11.0.0/24 Observability
20 10.20.0.0/24 Development
30 10.30.0.0/24 Staging
40 10.40.0.0/24 Production
50 10.50.0.0/24 Lab / Testing

Gateway IPs are the .1 address in each subnet, hosted on the Proxmox bridge:

  • 10.10.0.1 → VLAN 10
  • 10.11.0.1 → VLAN 11
  • 10.20.0.1 → VLAN 20
  • 10.30.0.1 → VLAN 30
  • 10.40.0.1 → VLAN 40
  • 10.50.0.1 → VLAN 50

3. Configure VLAN-Aware Bridge

Edit /etc/network/interfaces and define the main bridge vmbr0 as VLAN-aware.

vi /etc/network/interfaces

Example configuration (Ethernet uplink on enp87s0):

# Loopback
auto lo
iface lo inet loopback

# Primary uplink bridge (VLAN-aware)
auto vmbr0
iface vmbr0 inet static
    address 192.168.0.27/24
    gateway 192.168.0.1
    bridge-ports enp87s0
    bridge-stp off
    bridge-fd 0
    bridge-vlan-aware yes
    bridge-vids 10 11 20 30 40 50

Adjust the address, gateway, and bridge-ports values to match the environment.


4. Add VLAN Subinterfaces and Gateways

In the same file, add VLAN subinterfaces on vmbr0 for each subnet:

# VLAN 10 - Management
auto vmbr0.10
iface vmbr0.10 inet static
    address 10.10.0.1/24

# VLAN 11 - Observability
auto vmbr0.11
iface vmbr0.11 inet static
    address 10.11.0.1/24

# VLAN 20 - Development
auto vmbr0.20
iface vmbr0.20 inet static
    address 10.20.0.1/24

# VLAN 30 - Staging
auto vmbr0.30
iface vmbr0.30 inet static
    address 10.30.0.1/24

# VLAN 40 - Production
auto vmbr0.40
iface vmbr0.40 inet static
    address 10.40.0.1/24

# VLAN 50 - Lab / Testing
auto vmbr0.50
iface vmbr0.50 inet static
    address 10.50.0.1/24

Save and exit.


5. Apply Configuration Safely

Apply the updated configuration with minimal disruption:

ifreload -a

If SSH disconnects, reconnect to the same management IP (e.g. 192.168.0.27).
If reconnection fails, use the Proxmox console or physical access.


6. Validate Bridge and VLAN Interfaces

Check bridge status:

ip link show vmbr0

Expected: state UP, master is the bridge, and enp87s0 enslaved.

Check VLAN subinterfaces:

ip addr show | grep vmbr0.

Expected entries:

vmbr0.10: ... inet 10.10.0.1/24 ...
vmbr0.11: ... inet 10.11.0.1/24 ...
vmbr0.20: ... inet 10.20.0.1/24 ...
vmbr0.30: ... inet 10.30.0.1/24 ...
vmbr0.40: ... inet 10.40.0.1/24 ...
vmbr0.50: ... inet 10.50.0.1/24 ...

Verify routing:

ip route | grep 10.

Expected: routes to all VLAN subnets via vmbr0.


7. Smoke Tests from a VM

For a test VM attached to VLAN 20:

  • Net device in Proxmox: vmbr0, VLAN tag 20
  • Inside the VM, configure IP 10.20.0.10/24, gateway 10.20.0.1

From inside the VM:

ping -c3 10.20.0.1     # Gateway
ping -c3 10.10.0.1     # Management gateway

Both should succeed once routing and firewall (see ADR-0103) are in place.


8. Troubleshooting

Symptom: No connectivity from VM to gateway.

  • Confirm VLAN tag set on VM NIC in Proxmox (e.g. 20 for dev).
  • Check bridge-vids includes the VLAN ID:
    bridge vlan show
    
  • Verify vmbr0.20 is UP:
    ip link show vmbr0.20
    

Symptom: Proxmox loses external connectivity after ifreload -a.

  • Validate management IP / gateway in vmbr0 section.
  • Confirm upstream router is reachable:
    ping -c3 192.168.0.1
    
  • If required, restore backup:
    cp /etc/network/interfaces.backup-YYYYMMDD* /etc/network/interfaces
    ifreload -a
    

9. References